Apc ups signaling cable pinout ars technica openforum. I have used apc s powerchute in the past on standalone servers, but i would like to do this across multiple servers, some of which wont have the serial cable coming from the ups plugged in. Most of the units have a smartslot with the exception of sc and smc series which accepts an optional interface card providing features ranging from network connectivity to temperature and humidity monitoring. Connect the supplied interface cable to the 9pin computer interface port on the back panel of the ups. For protected servers, the included powerchutetm network shutdown software provides graceful. Solved connect to an apc upc general hardware forum. The ups features a transient voltage surgesuppression tvss screw for connecting the ground lead on surge suppression. The back ups model lines are only compatible with the personal edition software using the usb connection. Periodic battery selftest ensures early detection of a battery that needs to be replaced. What i need is a way to monitor the serial port in labview so that i can get information from the ups about its state ac power. There is an optional serial cable that allowed you to use the back ups units and our older powerchute business edition versions not the new 9. The ups provides protection for electronic equipment from utility power blackouts, brownouts, sags. The ups came with a serial cable labelled 9400625a which i have plugged in to a serial port on the server.
It offers plug and play funcionality among other things read something about in apc s site a long time ago which i. Apc ups network management cards allow for secure connection and control of an individual apc ups unit via web browser, commandline interface, or snmp. Apc ups setting the ip address in a network management card. Start the network management card device ip configuration utility. You can use either of these to connect the ups to your server. We just bought a cyberpower ups with a serial port.
In short, you only need a 3wire connection between the apc ups console. Apc smartups srt 3000va 2700watts 208v online 2u rm l6. See your ups operation manual on the apc website for more information. An apc network management card must be configured with network settings before it can communicate on the network. For protected servers, the included powerchute network shutdown software provides graceful. Installation and operation back ups xs connect the battery install powerchute personal edition software 1. Buy a apc back ups cs 500va300w 120vac tower ups serial 3 515r outlets and get great service and fast delivery. Apc smt750rmi2u smart ups 750va lcd rm 2u 230v dnexus. Install the software on a computer located on the same network as the apc ups. Monitoring a ups with nut on debian or ubuntu linux random bits. I used both the serial and usb cables which came with the ups. Our tutorial will teach you multiple ip address discovery procedures. Smartups ups operation manual apc ups, refurbished. Buy a apc smart ups srt 3000va 2700watts 208v online 2u rm l620p input 3 outlets usb serial smartslot and get great service and fast delivery.
Buy apc smartups 750va ups with smartconnect, pure sinewave ups battery backup, line interactive, 120v uninterruptible power supply smt750c, black. Now, you need to access the apc website and download the software named. Apr 17, 2017 i am new to snmp and perl, but not to linux and sysadmin. I then attempted to connect to the weird ethernet jack on the back and browse to 10. Apc smartups srt 3000va 2700w 208v online ups l620p.
Uninterruptible power supply ups free delivery possible on eligible purchases. Should work with apc powerchute or apcupsd ups server for linux. June 20 the information in this document is provided solely to allow communications with schneider electrics apcbrand devices via software. Apc srt8kxli smart ups srt 8000va 230v apc srt8kxli. Ensure that the usb cable connected to the ups is the last cable.
During startup, use the display interface to configure these settings. Apc smart ups serial connection on windows server 2012 r2. Apc ups network management cards allow for secure monitoring and control of an individual apc ups via web browser, command line interface, or snmp. Sleeve trs to db9 cable and connect it directly to the nmc2 into the. Use only the supplied cable to connect to the serial port. I have since wiped this and put windows 7 enterprise and reinstalled all the drivers and necessary so. Cd with software, documentation cd, installation guide, rack mounting support rails, smart ups signalling rs232 cable, usb cable. Nema 515p input and output 120v tower interface port smartslot all coasttec ups units undergo a 30step recertification process that includes new batteries, rigorous testing, and cosmetic repair. Creating direct connection to apc network enabled devices. If you are using powerchute software, and have connected the ups to a computer using serial, usb or network interface, you will be able to set. Apc backups pro 1500 usb not recognized microsoft community. Hence the standard software for shutting down your computer on a ups power loss signal is not helpful. If you use a ups that has a serial port with the correct version of powerchute it will work.
It came with powerchute plus for windows to do all the logging and admin. For operating systems with basic shutdown capabilities, ups cable interface kits are available for use with all apc upss with dedicated rs232 serial ports. The ups will not be used to maintain the computer running the labview program, but is for different equipment. You must use a special serial cable with different pinouts for smart and simple signaling to work. Free, secure and fast power ups software downloads from the largest open source applications and software directory. Apc shareups interface expander, 8port ap9207 connection. Would you like to learn how to access the apc ups console using a serial cable. When power fails, share ups notifies via apc software or cable kits, available separately all the connected servers of power problems and ensures that all servers are. I need to present an apc ups unit to solarwinds orion sam. Ups cables that provide dedicated connections between apc upss and desktops, workstations, and servers. Compatible with most apc upss that have a db9 serial port. Hi, if you connect to the ups serial port directly with your pc and a terminal program, it requires 2400 baud, 8 data bits, parity none, 1 stop bits, flow control none.
This document describes how to install the apc ups daemon. Buy a apc smart ups 1500va 980w 120v lcd tower ups 8 515r outlets usb serial network card and get great service and fast delivery. Omnismart 120v 700va 450w line interactive ups tower usb. Tutorial apc ups console access using the serial cable step by. Apc s nextgeneration connected smart ups enables you to monitor your power infrastructure online, anytime anywhere from our secure smartconnect web portal. The ups is connected via serial to a raspberry pi running apdupsd apcupsd a daemon for controlling apc upses which works fine as i can poll it manually. Apcs nextgeneration connected smartups enables you to monitor your power infrastructure online, anytime anywhere from our secure smartconnect web portal. I have attempted to connect via serial cable the apc serial cable nonetheless that i had to purchase because you can only use apc. Use the tcpip command to configure manual network settings to assign manual. In this tutorial, we are going to show you how to access the console of an apc ups using a serial cable and the software putty.
How do i configure apc network management card network. Its so easy to install on the laptop, then i just connect the ups to the laptop with an included usb cable, the open the software and it tells me the. Configure ups connection settings in apc smart ups 3000 xl. I couldnt get a response from the ups with a laptop connected to the units serial connection an rj45 jack in the back of the ups even using the apc supplied serial cable. Hi, i regularly use a laptop to configure several apc smart ups via command line and putty. I then tackled the job of reprogramming the runtime one of the smt1500s and experienced failure after failure. Check your hubs manual to learn whether the hub should be powered with an acdc adapter. The apc smt series smart ups 2u rackmount va700w ups with up to 9minutes runtime at full load is an advanced line interactive ups system to protect network servers, storage and associated equipment. Cd with software, smart ups signalling rs232 cable, usb cable, and users manual. The machine the ups protects is being changed from windows xp to windows server 2012. I am trying to access the management interface for a apc ups using the serial port. An extension cable lets your ups send signals over longer distances. Smt750rmi2u apc smart ups,500 watts 750 va,input 230v output 230v, interface port rj45 serial, smartslot, usb, rack height 2 u includes. Designed and manufactured by apc for over 23 years, smart ups is the worlds most trusted network ups with over 25 million units sold.
If you have the scroll lock on, hyperterminal will not communicate properly with an apc ups or accessory. Apc smt750rmi2u smart ups 750va lcd rm 2u 230v model. I cannot get my sua1500 to communicate with my win7 ultimate 64bit system and cant figure out why. Dec 16, 2010 once connected with the serial cable, i opened hyperterminal with the suggested settings and no luck. Configure battery packs on your apc ups black manticore. Sep 27, 2016 find answers to connecting apc ups 2200 via serial port from the expert community at experts exchange. The server and the ups are connected with genuine apc serial signaling cable. Jul 30, 2008 90 comments on monitoring a ups with nut on debian or ubuntu linux there are two different ways to monitor a ups with nut.
For a serial port connection, there are two different menus depending on whether the ups is operating in apc smart protocol mode or simple signalling mode this. Ideal ups for servers, pointofsale, routers, switches, hubs and other network devices. In this tutorial, we are going to show you how to access the console of an apc ups using a serial cable and the software. The ups provides a clean and reliable networkgrade power output, suitable for critical data and networking equipment. Cd with software, rack mounting brackets, rack mounting support rails, smart ups signalling rs232 cable, usb cable, user manual. It also contains a workaround for an ups firmware issue that causes killpower to execute repeatedly in a loop, resulting in the ups continually cycling power. The apc ups will receive an ip address automatically from the dhcp server.
For example, if you are running a serial version of apc s powerchute software, the apc ups service must be stopped prior to running the terminal program. A standard serial interface cable is incompatible with the ups. The smartups is a series of enterpriselevel uninterruptible power supplies ups made by american power conversion apc. Check that the powerchute business edition agent service is running, named apc pbe agent. Plugandplay external batteries ensures clean, uninterrupted power to the loads when adding extra runtime to the ups. Heres the information on the elusive apc smart signalling protocol used by their higher end units backups. Configuring apc nmc2 via terminal emulation schneider electric. The serial communications cable is not a standard rs232. Tutorial apc ups initial ip address configuration step. The apc ups can communicate with the linux system through either a rs232 or usb serial connection. Jul 25, 2006 in order to set up your ups to run two or more machines, youll have to use a network connection to tell the other machines what to do. Buy a apc smart ups srt 3000va 2700w 208v online ups l620p input 3 outlets usb serial smartslot and get great service and fast delivery. Implementation in smartups apc by schneider electric 85 rangeway road, north billerica, ma telephone.
Ill try and get powerchute plus on to windows 2012 but somehow i doubt it. Compare the best free open source power ups software at sourceforge. Smx1500rmi2u serial connection issue ups management. Or maybe i should also ask if there is a way to get one serial connection from the ups shared to multiple servers. The version of powerchute you use is dependent upon the model of ups you use.
I just purchased 3 apc back ups ess and i noticed they all have rj45 serial connections for the data port to connect to a pc to use powerchute software. Connect to a computer to use power management software. Enter the full ip address range of your network and click on the button to start the search for the ups. I simply want to connect to my apc sua3000 smart ups to configure the networking so that i can mon. The connected smart ups with a dedicated smartconnect ethernet port makes set up easy. You should see a driver called american power conversion usb ups.
If power is not restored my server must shutdown when the battery is exhausted. I ordered two of these ups, i connected one to server 2008 r2 machine and the other to a windows 7 pc. Normal 9 pin serial connections have txd on 3 and rxd on 2. Tutorial apc ups discover the ip address step by step. Apc smartups srt 3000va 2700watts 208v online 2u rm l620p. It supports connection of up to 8 servers to a single ups and issuance of ups shutdown comunication messages to each server through a local hardwired serial connection. Connect to your network and enjoy direct control apc ups network management cards allow for secure connection and control of an individual apc ups unit via web browser, commandline interface, or snmp. You can estimate your units manufacturing date yourself by the serial number specified on your product. It is subject to change without notice and is provided as is without warranty of any kind, express or implied. Login to follow, share, and participate in this space.
If you are using serial communications, check a that you are using the serial cable that came with the ups and b that it connects the serial port on the ups to the serial port on your computer. I tried to connect it into computer through serial port, but it turns out it requires special wiring to do so. Convenient, easy to connect, hotswappable battery modules provide battery replacement without powering down. To discover the apc ups ip address, access the apc. In order to set up your ups to run two or more machines, youll have to use a network connection to tell the other machines what to do. Battery failure notification provides earlywarning fault analysis on batteries enabling timely preventive maintenance. The third and fourth digits indicate the year your unit was manufactured, while the following 2. In the event of a prolonged power outage, should the apc ups lose most of its battery capacity, it can tell the linux box to perform a safe shutdown. I have an oldish apc smart ups 3000, and i would like to connect it to my server running windows server 2012 with 3 hyperv vms, enabling me to shut down the vms and the host server in the event of a power cut. The connected smartups with a dedicated smartconnect ethernet port makes set up easy. The smartups is a series of enterpriselevel uninterruptible power supplies ups made by.
I am new here, so at the beginning i want to say hello everybody. Nov 18, 2012 my linux nas server connected to apc smartups using usb cable and i would like to detect a power failure. Nov 23, 2015 apc back ups pro 1500 usb not recognized. Serial and usb ports cannot be used simultaneously. Apc supplies a special serial cable with each ups that has a serial console, because their interface doesnt match the defacto standard initially used on the old ibm pcat. The configurable notification features keep you informed of problems as they occur. A free alternative to powerchute is the free software project apc ups daemon apcupsd, which supports. Apc smartups 620va w 4outlets, serial micro center. Enables centralized management via the apc infrastruxure manager. Ive got an old apc ups apc back ups pro 420, model. Connect the supplied usb software interface cable to the data port, and the other end to a computer with access to the internet.
Feb 04, 2015 this video features the configuration of static ipv4 address in a network management card os a apc ups rt 6000. Apc s cable for that ups has a different pinout than a regular serial cable. The apc by schneider electric smart ups product name is a high performance uninterruptible power supply ups. The last 6 apc ups i have purchased over the years always came with a usb connection. Cd with software, smart ups signalling rs232 cable, usb cable, user manual. The information provided in the apc software firmware download is provided for general informational purposes only. Learn how to discover the ip address on an apc ups. I figured the apc back ups wasnt doing its job so last month we bought a shiny new smart ups.
Apc backups cs 500va300w 120vac tower ups serial 3 5. Connection to serial port via usbserial adapter smart. Smart ups units are highly efficient at low, medium and high load levels. Rated 5 out of 5 by jeff from read all specs before buying the ups is working fine and was plug and play. How to find your apc ups factory warranty information. I want to configure ups connection settings with the help of nmc terminal, how to configure ups connection settings in apc smart ups 3000 xl. First, you need to connect your apc ups to the network. Declaration of conformity uninterruptible power supply smart ups over 1. How do i configure and use my apc smartups under debina ubuntu rhel centos fedora scientific linux operating system for power management. Up until a week ago the laptop was windows 7 starter edition. Apc suaxl smart ups xl va 120 v ups with usb and serial interface. To cut long story short, i need to connect my ups via serial cable rj4550 db9f and have communication with it via hyperterminal or something like that. Serial and usb cable, as it may lead to unexpected shutdown behavior. Downloaded another emulation program called securecrt but still have the same screen.